Fire sprinkler systems are a frontline defense against fire-related risks and are critical in protecting people and property. To help ensure these systems are operational, it is essential to be aware of threats that can damage them. One threat, microbiologically influenced corrosion (MIC), is significant but often overlooked. Over time, MIC can compromise the integrity of a sprinkler system, leading to leaks, blockages and even complete failure. Awareness and proactive management of this issue are essential for long-term safety and performance.
MIC is a form of corrosion caused, concentrated or accelerated by the presence and activities of microorganisms. These microbes can create highly corrosive environments that can erode metal. The corrosion often occurs in stagnant or low-flow areas of the piping, where biofilms can more easily establish and thrive. MIC can be found in dry pipe, wet pipe and pre-action systems.
Over time, the microbiological activity can lead to pitting, tuberculation (the formation of iron-oxide mounds on a pipe’s interior), and the degradation of pipe material, which can compromise the integrity of the sprinkler system. MIC can also cause obstructions in the piping, reduce water flow, cause leaks or malfunctions, and lead to system failure.
New fire sprinkler systems are not immune to MIC, and preventing these instances requires proactive design, installation and maintenance strategies. NFPA 13, Standard for the Installation of Sprinkler Systems, published by the National Fire Protection Association (NFPA), requires water supplies for sprinkler systems to be evaluated for the existence of microbes or conditions that support MIC. Property owners should work with licensed professionals to develop a process to control MIC when these conditions are detected. Options include:
Additionally, systems should be designed to prevent air pockets and stagnant water zones and ensuring consistent flow throughout the piping network. Installing fire protection systems with pipes and sprinklers that use corrosion-resistant materials can also prevent or delay MIC.
Warning signs of MIC can be subtle and easy to miss. Common indicators include leaks, water discoloration, foul odors, internal deposits, exterior corrosion and recurrent issues despite regular maintenance. Regular system inspections, especially in areas prone to low flow or stagnation, are essential for detecting early signs of MIC. Regular flushing, water quality monitoring at strategic locations (e.g., system riser main drains, the underground water main loop, remote connection points, fire pump reservoirs and tanks) and routine visual inspections of system components (e.g., joints, pipe fittings and sprinkler head orifice seats) can help detect MIC. Property owners should adhere to the requirements of NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, which requires regular inspections to detect early signs and symptoms of corrosion.
If MIC is confirmed, early intervention is key to preventing long-term damage and maintaining the reliability of fire protection systems. Common treatment options include flushing the system, chemical cleaning with nontoxic and environmentally friendly chemicals and replacing infected sections of piping. In some instances, chemical treatment is not recommended because it can accelerate pipe corrosion.
Long-term MIC prevention may also include modifying system components or flow patterns to reduce stagnant zones and improve water circulation. Consistent documentation and follow-up inspections are key to ensuring the system remains reliable and compliant with fire protection standards. Most importantly, property owners should work with a qualified contractor with experience in treating MIC in fire sprinkler systems.
Preventing and responding to MIC in fire sprinkler systems requires a proactive approach. By implementing best practices and remaining vigilant, building owners and facility managers can safeguard the integrity of the sprinkler system and help ensure reliable fire protection. Contact us for more risk management solutions.